Solar calculators that do the whole check

Most free wire calculators check voltage drop and stop there. This one also checks ampacity, applies the ambient-temperature and bundling derates, and sizes continuous circuits at 125% — then tells you which limit actually governed.

NEC ampacity & derating tables Cold-temperature Voc check Nothing uploaded
Wiring & safety
Sizing the system
Money

Why two checks, not one

A conductor has to satisfy two independent limits. Ampacity is how much current it can carry without overheating — that is a fire question, and it gets worse in hot attics and in bundles. Voltage drop is how much voltage you lose over the run — that is a performance question, and it dominates on long low-voltage DC runs. On a 5 ft battery cable ampacity governs; on a 100 ft 12 V run to a shed, voltage drop can force a conductor four sizes larger than ampacity alone would suggest. A calculator that checks only one of them will confidently give you the wrong answer roughly half the time.

Which code edition is this based on?

The embedded tables follow the NEC values in common use: Table 310.16 for allowable ampacity, Table 310.15(B)(1) for ambient correction, Table 310.15(C)(1) for bundling, Chapter 9 Table 8 for conductor resistance, and 690.7 for cold-temperature voltage. Code editions and local amendments differ — always confirm against the edition your inspector enforces.

Why is my string limited to fewer panels than I expected?

Because panels make more voltage when they are cold. A module rated 40 V open-circuit at 25 °C produces about 44 V at −10 °C. Multiply that across a string and a system that looks fine on the datasheet can exceed the inverter's maximum on the first frosty morning. This site applies the cold correction before counting modules, which is why it will often allow fewer panels per string than a naive calculator.

Can I rely on this for a real installation?

Use it to plan, to sanity-check a quote, and to understand the trade-offs. Do not use it as the sole basis for an installation. Wiring errors cause fires, and DC arc faults are unforgiving. Have the design reviewed by a licensed electrician or solar installer who can inspect the actual site.

Safety note. These tools do arithmetic using published code tables. They cannot see your site, your equipment, your ambient conditions or your local amendments, and they are not a substitute for a licensed electrician. Electrical work done wrong causes fires and electrocution — have any real installation designed or reviewed by a qualified professional and inspected as your jurisdiction requires.

🔌 Wire Size Calculator

Checks ampacity and voltage drop, with the derates applied — then shows every size so you can see why.

📉 Voltage Drop Calculator

Drop across a known conductor size, for DC or AC.

🥶 String Sizing & Cold Voc Check

Panels make more voltage when cold. This is the check that keeps a string under the inverter's limit in January.

📋 Load Audit

List what you actually run. Everything else on this site starts from this number.

🔋 Battery Bank Sizer

Rated capacity is not usable capacity — depth of discharge, cold and inverter losses all take a share.

☀️ Solar Array Sizer

How many watts of panel it takes to actually refill what you use.

🎛️ Charge Controller Sizer

MPPT and PWM are limited by different things, so they size differently.

🔁 Inverter Sizer

Continuous rating covers what runs; surge rating covers what starts.

💰 Solar Payback

Year by year, with electricity prices rising and panels slowly degrading.

🧮 Appliance Running Cost

What a device costs to run, per day, month and year.

WattBench — 10 solar and off-grid tools using published NEC tables. Every formula verified against worked examples before release.

© 2026 WattBench · Planning aid only — not a substitute for a licensed electrician